KG Wastewater Treatment Industrial Ozone Generator High Ozone Concentration PPM
1.Applications
Ozone be used in chemical, petroleum, papermaking, textile, fine chemical and flavors and fragrances industry as the oxidant, catalyst.
Its super-oxidation capacity and easy to cut off the associative key of Alkenes, Alkynes, and Benzene organics, increase the process oxidation, synthesis of new compounds.
Recently years, ozone is widely used in industrial sewage water treatment as it has the ability of high kill rate of bacteria, viruses and other microorganisms with high speed, and complete removing the organic compounds and other pollutants without creating secondary pollution, also can reduce the biological oxygen demand (BOD) and chemical oxygen demand (COD), remove nitrite, suspended solids and decolorization in water.
2.Technical Description
1. Use enamel tubes for the core parts of ozone generator.
2. In order to ensure the safety and continuously operating of ozone discharge, each discharge cell is equipped with separated safety appliance. Single discharge unit failure does not affect the normal operation of other units.
3. Discharge chamber
1. Use stainless steel for the case, resistant to rust & corrosion, and can effectively prevent the cooling water fouling.
4. High frequency of power supply
1. Precise setting the Voltage and Working frequency. Output frequency resolution can be up to ± 0.1Ht. Voltage Precision ±1V.
2. Has a perfect overload, automatic current-limiting, overpressure, short circuit, lack of phase and power-off protection.
3. SPWM modulation technology. Power factor COSθ can be 0.9.
5. High voltage transformer
1. Using Mn-Zn ferrites for magnetic core. Small wastage of iron core / low Resistivity / low temperature coefficient / high rate of dynamic permeability under high frequency working condition.
2. Using special cables of high frequency & stranded conductor to reduce the skin effect of high-frequency current.
NT-DGY 1.6 Ozone System Technical Parameters:
Item |
NT-DGY1.6 Ozone Generator |
Ozone Output |
1.6KG/Hr |
Power Supply Voltage |
380 3PH 50HZ |
Power |
15.8 KW/HKGO3 |
Operating Voltage |
3800V-4200V |
Working Frequency |
800 Hz |
Ozone Concentration |
80-110MG/L |
Oxygen Feed Flow Rate |
12-15 NM3/HKGO3 |
Air Source Dew Point |
≤-45℃ |
Working Pressure of Discharge chamber |
0.05-0.1Mpa |
Outlet Air Temperature |
≤30℃ |
Inlet Cooling Water Temperature |
≤20℃ |
Cooling Water Temperature Rise |
4-6℃ |
Cooling Water Flow |
2-2.5M3/HKGO3 |
Remark:
1.Different working condition there will be10%-20% different of ozone capacity.
2.Kg ozone machine configuration can be custom-made according to customers demand
3.KG ozone generator also popular used in Jeans color fading area.